Factory-direct transformer manufacturer · Xuzhou, China

IEC 60076 · IEEE C57.12 · 50 Hz and 60 Hz designs

Solar, Wind and BESS Transformer Guide

Solar, Wind and BESS Transformer Buying Guide

Buying guide · Tianhua Transformer engineering team

Quick answer

Renewable plants need step-up transformers designed for inverter duty: low losses at partial load, harmonic-rated windings, electrostatic shields and often a double-split LV winding so one transformer serves two inverters. Tianhua builds single step-up units and integrated step-up substations that combine the transformer, MV switchgear and PCS for solar, wind and battery storage plants.

Inverter output (typically 0.4–0.8 kV) is stepped up to the collection voltage of 10, 20, 33 or 35 kV, then to the grid through a power transformer.

Get a quote in 24 hoursDownload catalogue

Double-split step-up transformer for solar PV, built by Tianhua
Double-split step-up transformer for solar PV, built by Tianhua

At a glance

LV side0.4–0.8 kV inverter output
MV side10, 20, 33 or 35 kV collection voltage
DesignsDouble-split, single LV, pad-mounted step-up, integrated skids
TypesOil-immersed, dry-type or pad-mounted
IntegratedTransformer + RMU + LV cabinet, optional PCS, from 0.5 MW upward
Grid step-upPower transformers 35–220 kV

1. Designed for inverter duty

  • split LV windings to connect two inverters without circulating current
  • electrostatic shield between windings to reduce noise and common-mode voltage
  • design for harmonic content and the daily load cycle
  • copper busbar outlets on the coil top for faster cabling

2. Double-split or single LV winding?

Double-splitSingle LV winding
Inverters per transformerTwo, isolated from each otherOne, or several in parallel
Typical useCentral inverter solar plants, BESS PCS blocksString inverter plants, small systems
BenefitFewer transformers, independent operation of each halfSimpler and lower cost

3. Losses and the daily load cycle

Solar transformers run lightly loaded in the morning and evening and are idle at night, but they stay energised. Low no-load loss therefore saves energy every hour. Battery storage transformers charge and discharge, so the design must handle power flowing both ways.

4. Integrated step-up substations

For faster construction, an integrated step-up substation combines the transformer, ring main unit and LV cabinet, and can include the inverter or PCS, in one skid or enclosure from 0.5 MW upward for 6–35 kV collection grids. It is tested as a unit in the factory. Read the compact substation guide.

5. Wind turbines

Wind step-up transformers are designed for variable load, vibration and, offshore, a corrosive environment. Give the turbine output voltage, the collection voltage and where the transformer will sit (nacelle, tower base or outside).

6. Connecting to the grid

The collection network feeds a main step-up power transformer, usually 110 kV or 220 kV, often with an on-load tap changer to meet grid code voltage requirements. Read the power transformer guide.

7. What to send for a quotation

  • plant size (MW) and number of blocks
  • inverter or PCS model, output voltage and number per block
  • collection voltage and grid connection voltage
  • oil, dry or pad-mounted preference, and integrated skid or separate units
  • site conditions and destination

Who makes these transformers

Transformer workshop at the Tianhua factory in Xuzhou, China

This guide is written by the engineering team of Jiangsu Tianhua Transformer Co., Ltd., a transformer manufacturer founded in 2013 in Xuzhou, Jiangsu, China. Every unit is designed, built and tested in our own 107,000 m² plant: core cutting, winding, drying, resin casting, tanks, radiators, assembly and testing. You deal directly with the factory engineers.

  • 500+ employees, including 7 senior engineers
  • ISO 9001 quality system; IEC, IEEE / ANSI and GB designs
  • SSZ11-40000/110 passed short-circuit and full type tests at a national test center
  • Exported to more than 30 countries and regions

About Tianhua · Factory and testing · Certificates · Projects

Frequently asked questions

What is a double-split transformer?

A transformer with two LV windings that can run together or independently, so one unit serves two inverters.

Do you supply BESS step-up skids?

Yes. Integrated step-up substations can include the PCS, transformer, RMU and LV cabinet in one enclosure.

Which voltages are typical for solar transformers?

0.4–0.8 kV on the inverter side and 10, 20, 33 or 35 kV on the collection side.

Why do solar transformers need low no-load loss?

They stay energised day and night but are fully loaded only for a few hours, so no-load loss is a large part of their lifetime energy cost.

Can a battery storage transformer work in both directions?

Yes, BESS transformers are designed for power flow in both directions during charging and discharging.

Do you make the main grid step-up transformer too?

Yes, power transformers from 35 kV to 220 kV and up to 360 MVA.

Request a renewable energy transformer quotation

Send capacity, voltages, standard, quantity and destination. Our engineers reply with a datasheet and price within 24 hours.

Email sale@thatransformer.comWhatsAppCall Ivy Xiao

Written by the Tianhua Transformer engineering team, Xuzhou, China. Last updated November 2026.