Utilities & grid · 0.4 kV to 220 kV
One factory for the whole network, from 220 kV transmission substations down to 0.4 kV distribution transformers on poles and pads. Every unit ships with its test report.

Quick answer: Tianhua supplies utilities and EPC contractors with 220 kV and 110 kV power transformers, 35 kV substation transformers, and 10–35 kV distribution transformers. We also supply pole-mounted and pad-mounted units, compact substations and 12 kV switchgear. For the loss level, choose S11 for the lowest price, S13 for low-loss tenders, S20 / S22 for energy-efficiency grades, or SH15 amorphous alloy for the lowest no-load loss.
Tenders specify loss levels or energy-efficiency grades.
Our answer: We build every catalogue loss level, from S11 to grade 1 S22 and SH15 amorphous alloy, with the full loss tables published per rating.
Rural networks run lightly loaded and peak seasonally.
Our answer: Amorphous alloy SH15 cuts no-load loss. Our high-overload transformers ride through irrigation and harvest peaks.
Coastal and humid sites corrode equipment.
Our answer: We supply stainless steel tanks and heavy coating systems up to C4-M, packed to protect the coating in transit.
Mixed IEC and North American networks.
Our answer: We build IEC 60076 / GB designs at 50 Hz, plus pole- and pad-mounted units with IEEE C57.12 features at 60 Hz.

Transmission substation220 kV / 110 kV

Sub-transmission and primary substations35 kV

Medium-voltage distribution10 / 20 / 33 kV to 0.4 kV

Compact substations6–10 kV

Overhead and underground feedersPole and pad
Supplying a utility or EPC tender?
Send your ratings, voltage, loss level and quantities. We quote directly from our factory, with test reports for every unit, within 24 hours.
These points come straight from the Tianhua product catalogue. Each card names the network problem and how the design of the product addresses it.

Solves: Harmonics and poor supply quality on distribution networks

Solves: High standing losses and noise in urban and rural networks

Solves: Loss, noise and short-circuit weakness of stacked cores

Solves: Energy wasted by lightly loaded rural and urban grids

Solves: Short-circuit failures and hot spots in 35 kV substations

Solves: Long build times for traditional substation rooms

Solves: No space for a full substation in cities and on building sites
No-load loss is drawn 24 hours a day, whatever the load. The table uses catalogue no-load loss for a 400 kVA, 10 kV transformer × 8,760 hours per year.
| Series | No-load loss (W) | No-load energy per year (kWh) | Saving vs S11-M per year (kWh) |
|---|---|---|---|
| S11-M | 570 | 4,993 | — |
| S13-M | 410 | 3,592 | 1,401 |
| S20-M (grade 2) | 370 | 3,241 | 1,752 |
| S22-M (grade 1) | 330 | 2,891 | 2,102 |
| SH15-M amorphous | 200 | 1,752 | 3,241 |
Calculated from the Tianhua catalogue. Multiply by your tariff and the number of units to compare the total cost of ownership.
220kV power transformer31.5–360 MVA, OLTC ±8×1.25%, YNd11View specifications →
110kV power transformer6.3–63 MVA, OLTC 110±8×1.25%View specifications →
35kV power transformer S11 / SZ11630–31,500 kVA, off-circuit or on-loadView specifications →
S13-M distribution transformer30–3,150 kVA, 6–10 kV / 0.4 kVView specifications →
S20 / S22 energy-efficiency transformerEnergy efficiency grade 2 and grade 1View specifications →
SBH15-M amorphous alloy transformerAmorphous core, lowest no-load lossView specifications →
Single-phase pole-mounted transformer5–167 kVA, 2.4–34.5 kV, 120/240 VView specifications →
Three-phase pad-mounted transformer45–5,000 kVA, dead front, loop feedView specifications →
YB prefabricated substation30–1,600 kVA, 10 kV, ring or terminalView specifications →| Application | Recommended | Rating | Why |
|---|---|---|---|
| Grid substation 220 kV | 220kV power transformer | 31.5–360 MVA | OLTC, ONAN/ONAF/OFWF cooling |
| Interconnecting 220 / 110 / 35 kV | 220kV three-winding autotransformer | 31.5–240 MVA | Three windings, YNa0d11 |
| Primary substation 110 kV | 110kV power transformer | 6.3–63 MVA | OLTC, YNd11 |
| 35 kV substation | 35kV power transformer S11 / SZ11 | 630–31,500 kVA | Off-circuit (S11) or on-load (SZ11) |
| Urban 10 kV distribution | S13-M distribution transformer | 30–3,150 kVA | Low loss, fully sealed |
| Efficiency-grade tenders | S20 / S22 energy-efficiency transformer | 30–2,500 kVA | GB 20052-2020 grade 2 / 1 |
| Rural, lightly loaded | SBH15-M amorphous alloy transformer | 30–2,500 kVA | Lowest no-load loss |
| Direct 33 kV rural supply | 33kV / 35kV distribution transformer | To order | 33 / 0.415 kV, copper windings |
| North American overhead | Single-phase pole-mounted transformer | 5–167 kVA | 120/240 V secondary |
| Underground residential | Three-phase pad-mounted transformer | 45–5,000 kVA | Loop feed, bay-o-net fuses |
Real photos from our plant in Xuzhou. Every unit is built, tested, packed and shipped by our own team.



South America · 110 kV transformer supply
Transformer oil was sourced in Argentina and delivered straight to site with the customer’s approval. This cut the total transformer cost by about 6%.
Southeast Asia · substation equipment, C4-M corrosion class
We used a 200 µm coating system with protective packaging. The equipment passed the corrosion inspection on the first attempt.
Saudi Arabia · transformer installation in Riyadh
The transformer was installed on its foundation in Riyadh. See project details →
| Manufacturer | Jiangsu Tianhua Transformer Co., Ltd. (brand THA 天华) |
|---|---|
| Business type | Factory and manufacturer, not a trading company |
| Location | No. 105 Xuhai Road, Economic and Technological Development Zone, Xuzhou, Jiangsu, China |
| Products for this application | 220 kV and 110 kV power transformers, 35 kV power transformers, 10–35 kV distribution transformers (S11, S13, S13-M·RL, S20, S22, SH15), pole and pad-mounted transformers, YB and ZGS compact substations, KYN28A-12 switchgear |
| Standards | GB 1094 / IEC 60076; dry-type to GB 1094.11 / IEC 60076-11; energy efficiency to GB 20052-2020 |
| Export markets | Indonesia, Kazakhstan, Vietnam, Russia, the Philippines and others |
| Sales contact | Ivy Xiao · +86 136 8498 9973 · sale@thatransformer.com |
Related article: How to Specify Distribution Transformers for a Utility Tender · All articles
Jiangsu Tianhua Transformer Co., Ltd. in Xuzhou, Jiangsu, is a transformer factory that supplies utilities and EPC contractors from 0.4 kV to 220 kV, and exports to markets including Indonesia, Kazakhstan, Vietnam, Russia and the Philippines.
From 0.4 kV distribution up to 220 kV transmission. That covers 220 kV and 110 kV power transformers, 35 kV substation transformers, 10–35 kV distribution transformers, pole and pad-mounted units, compact substations and 12 kV switchgear.
At 400 kVA the catalogue no-load loss is 570 W for S11-M, 410 W for S13-M, 330 W for S22-M and 200 W for SH15-M amorphous alloy. Choose by your tender’s loss limits and energy tariff.
Yes. We design to the utility specification and confirm it in drawing approval before production. Type tests and third-party witness testing are available on request.
Yes. Pole-mounted and pad-mounted units are built for 60 Hz North American networks, and power and distribution transformers can be designed for 50 or 60 Hz.
Send your single-line diagram or equipment list. Our engineers reply with a proposal and price within 24 hours.
Prefer to browse? See all oil-immersed distribution products →
Last updated November 2026. Technical data from the Tianhua product catalogue.