EV charging · fleet depots · charging hubs
Transformers and compact substations to bring medium-voltage supply to public fast-charging hubs, bus and truck depots, and fleet yards. Factory-built and tested, ready to connect.
Factory-direct · Reply within 24 hours · Test report with every unit

Quick answer: an EV charging site needs a transformer or compact substation to step the utility's medium voltage down to the charger supply voltage. Tianhua supplies three-phase pad-mounted transformers (45–5,000 kVA), ZGS and YB box substations, S13 / S20 / S22 low-loss distribution transformers, dry-type transformers for indoor car parks, and 20 ft prefabricated cabin substations.
Long waits for a grid connection and equipment.
Our answer: Factory-assembled box and cabin substations arrive ready to connect, which shortens site work.
Peaky loads from DC fast chargers.
Our answer: ZGS combined substations have strong overload capacity and short-circuit resistance, per our catalogue.
Little space at forecourts and car parks.
Our answer: Compact ZGS and pad-mounted units have a small footprint; dry-type transformers go indoors with no oil.
Energy cost when chargers sit idle at night.
Our answer: Low-loss S13, S20 and S22 transformers cut the no-load loss that is drawn 24 hours a day.

Utility medium-voltage supply10–35 kV

Step-down at the siteMV to charger voltage

Indoor car parks and depotsNo oil indoors

Charging with battery storageContainerised
Planning a charging site?
Tell us the number of chargers, their power and your supply voltage. We size the transformer or substation and reply with a price within 24 hours.
These points come straight from the Tianhua product catalogue.

Solves: No room for a substation building at the site

Solves: Needing a complete, tested set fast

Solves: Slow site work for charging-plus-storage

Solves: Fire safety in indoor car parks
| Charging site | Recommended | Rating | Why |
|---|---|---|---|
| Public fast-charging hub, outdoor | Three-phase pad-mounted transformer | 45–5,000 kVA | Dead front, loop feed, compact |
| Forecourt or retail car park | ZGS American-type box substation | 30–2,500 kVA | Small footprint, overload capacity |
| Bus or truck depot | YB prefabricated substation | 30–1,600 kVA | Complete set, separate compartments |
| Underground or indoor car park | SC(B)13 cast resin transformer | 30–2,500 kVA | No oil, low partial discharge |
| Charging with battery storage | Prefabricated cabin substation | 20 ft container | LV, transformer, RMU in one unit |
| Low running cost at idle | S20 / S22 energy-efficiency transformer | 30–2,500 kVA | Efficiency grade 2 / 1 |
Three-phase pad-mounted transformer45–5,000 kVA, loop feed, dead frontView specifications →
ZGS American-type box substation6–10 kV, 30–2,500 kVA, IP33View specifications →
YB prefabricated substation10 kV, 30–1,600 kVA, outdoorView specifications →
S20 / S22 energy-efficiency transformerEnergy efficiency grade 2 and 1View specifications →
SCB18 grade 1 dry-type transformerIndoor, grade 1, smart coolingView specifications →
Prefabricated cabin substation20 ft cabin with RMU and LVView specifications →Real photos from our plant in Xuzhou. Every unit is built, tested, packed and shipped by our own team.



| Manufacturer | Jiangsu Tianhua Transformer Co., Ltd. (brand THA 天华) |
|---|---|
| Business type | Factory and manufacturer, not a trading company |
| Location | No. 105 Xuhai Road, Economic and Technological Development Zone, Xuzhou, Jiangsu, China |
| Products for this application | Three-phase pad-mounted transformers, ZGS and YB box substations, S13 / S20 / S22 distribution transformers, SCB13 / SCB18 dry-type transformers, prefabricated cabin substations, KYN28A-12 switchgear |
| Standards | GB 1094 / IEC 60076; dry-type to GB 1094.11 / IEC 60076-11; energy efficiency to GB 20052-2020 |
| Export markets | Indonesia, Kazakhstan, Vietnam, Russia, the Philippines and others |
| Sales contact | Ivy Xiao · +86 136 8498 9973 · sale@thatransformer.com |
Related article: How to Size a Transformer for an EV Charging Station · All articles
Jiangsu Tianhua Transformer Co., Ltd. in Xuzhou, Jiangsu, manufactures pad-mounted transformers, box substations and dry-type transformers for EV charging hubs and fleet depots, and exports to markets including Indonesia, Kazakhstan, Vietnam, Russia and the Philippines.
Most outdoor sites use a three-phase pad-mounted transformer or a compact box substation that steps the utility medium voltage down to the charger supply voltage. Indoor car parks use dry-type transformers. Send the number and power of your chargers and we size it for you.
Yes. YB and ZGS box substations and 20 ft cabin substations combine the transformer, switchgear and LV distribution, assembled and tested in our factory.
Yes. Pad-mounted units are built for 60 Hz networks with IEEE C57.12 features, and other transformers can be designed for 50 or 60 Hz.
Send your single-line diagram or equipment list. Our engineers reply with a proposal and price within 24 hours.
Prefer to browse? See all pad-mounted transformer products →
Last updated November 2026. Technical data from the Tianhua product catalogue.