The S13-M·RL uses a three-dimensional wound triangle core. Compared with a stacked-core transformer, no-load loss is 18–28% lower, no-load current 50–60% lower and noise 5–10 dB lower, with higher short-circuit strength. Ratings 30–3,150 kVA at 6–10 kV / 0.4 kV. Made by Jiangsu Tianhua Transformer Co., Ltd. in Xuzhou, China.
Series
S13-M·RL, three-phase, fully sealed, 3D wound core
Rating
30–3,150 kVA
HV / LV
6 / 6.3 / 10 kV to 0.4 kV
Vector group
Yyn0 or Dyn11
Tapping
±5% or ±2×2.5%
Certification
National PCCC energy-saving certified product
Manufacturer
Jiangsu Tianhua Transformer Co., Ltd., Xuzhou, China
Low loss: seamless magnetic circuit with no joints, no-load loss 18–28% below stacked cores
No-load current reduced 50–60%
Low noise: 5–10 dB quieter than stacked-core oil transformers
High mechanical strength: round core section gives better short-circuit withstand
Lighter core and compact triangular layout
Type designation: S13-M·RL-□/□
S: three-phase
13: performance level code
M: fully sealed
R: wound core
L: three-dimensional (triangle)
□: rated capacity (kVA) / voltage class (kV)
S13-M·RL 10kV rating table
Model
kVA
No-load loss (W)
Load loss Dyn11 (W)
Load loss Yyn0 (W)
No-load current (%)
Impedance (%)
S13-M·RL-30
30
80
630
600
2.3
4.0
S13-M·RL-50
50
100
910
870
2.0
4.0
S13-M·RL-80
80
130
1,310
1,250
1.9
4.0
S13-M·RL-100
100
150
1,580
1,500
1.8
4.0
S13-M·RL-125
125
170
1,890
1,800
1.7
4.0
S13-M·RL-160
160
200
2,310
2,200
1.6
4.0
S13-M·RL-200
200
240
2,730
2,600
1.5
4.0
S13-M·RL-250
250
290
3,200
3,050
1.4
4.0
S13-M·RL-315
315
340
3,830
3,650
1.4
4.0
S13-M·RL-400
400
410
4,520
4,300
1.3
4.0
S13-M·RL-500
500
480
5,410
5,150
1.2
4.0
S13-M·RL-630
630
570
6,200
6,200
1.1
4.5
S13-M·RL-800
800
700
7,500
7,500
1.0
4.5
S13-M·RL-1000
1,000
830
10,300
10,300
1.0
4.5
S13-M·RL-1250
1,250
970
12,000
12,000
0.9
4.5
S13-M·RL-1600
1,600
1,170
14,500
14,500
0.8
4.5
S13-M·RL-2000
2,000
1,510
17,800
17,800
0.8
To order
S13-M·RL-2500
2,500
1,780
20,700
20,700
0.7
To order
S13-M·RL-3150
3,150
2,100
24,300
24,300
0.7
To order
Impedance for 2000–3150 kVA is designed to customer requirements.
Data from the Tianhua product catalogue. Capacity, voltage ratio, vector group, impedance, losses and dimensions can be designed to your specification.
Applications
Factories, rural and urban distribution networks
Noise-sensitive residential sites
Pole-mounted and compact substations
Standards and testing
Designed and tested to GB 1094 and IEC 60076; loss levels to the series data above. Routine tests on every unit before shipment (ratio, vector group, winding resistance, no-load and load loss, impedance, applied and induced voltage) with the test report supplied. Type tests and third-party witness testing on request.
How to order
Send us
rated power and quantity
primary and secondary voltage, vector group and tapping range
standard (IEC, IEEE / ANSI, GB or your utility specification) and frequency
any loss limits or efficiency rule
site conditions: altitude, ambient temperature, indoor or outdoor, corrosion
destination port and preferred Incoterm
What happens next
datasheet and price within 24 hours
drawings for your approval
production, typically 4–6 weeks after drawing approval and advance payment
routine tests and test report; witness test on request
Jiangsu Tianhua Transformer Co., Ltd. designs, builds and tests this transformer in its own 107,000 m² plant in Xuzhou, Jiangsu, China. Founded in 2013, Tianhua is a manufacturer, not a trading company: you deal directly with our engineers, and inspectors are welcome to witness the factory acceptance test.
500+ employees, including 7 senior engineers
ISO 9001 quality system; IEC, IEEE / ANSI and GB designs
Its core is three continuously wound frames arranged in a triangle. There are no air-gap joints, so magnetic flux follows the steel grain, which lowers no-load loss and noise.
How much quieter is the S13-M·RL?
5–10 dB lower than a stacked-core oil transformer of the same rating.
What is the loss of a 500 kVA S13-M·RL?
No-load loss 480 W; load loss 5,410 W (Dyn11) or 5,150 W (Yyn0); impedance 4%.
How long does the S13-M·RL wound core transformer take to make?
Typically 4–6 weeks for standard units after drawing approval and advance payment. We confirm the date for your quantity in the quotation.
Can the S13-M·RL wound core transformer be built to my specification?
Yes. Rating, voltage ratio, vector group, impedance, losses, accessories and dimensions can be designed to your specification and standard.
How is the S13-M·RL wound core transformer shipped?
In a container or on a flat-rack, filled with oil and ready to install. Sealed units do not need core lifting after normal transport.
What warranty does Tianhua give?
The warranty is 1 to 2 years depending on the product and size, confirmed in the quotation and sales contract.