A split-winding transformer has two LV windings fed by one HV winding, so each section supplies a separate bus. It limits short-circuit current, reducing the need for current-limiting reactors in power plants and large substations. Made by Jiangsu Tianhua Transformer Co., Ltd. in Xuzhou, China.
Construction
Oil-immersed, two split LV windings
Cooling
ONAN / ONAF
Capacity & voltage
Designed to project
Frequency
50Hz or 60Hz
Manufacturer
Jiangsu Tianhua Transformer Co., Ltd., Xuzhou, China
Standard design data. Capacity, voltage ratio, vector group, impedance, losses, cooling and dimensions can be designed to your specification.
Applications
Thermal and hydro power plant auxiliary systems
Large substations
Solar plants with twin inverters
Standards and testing
IEC 60076, GB 1094. Routine tests are performed on every unit before shipment and the test report is supplied; type tests and witness testing are available on request.
How to order
Send us
rated power and quantity
primary and secondary voltage, vector group and tapping range
standard (IEC, IEEE / ANSI, GB or your utility specification) and frequency
any loss limits or efficiency rule
site conditions: altitude, ambient temperature, indoor or outdoor, corrosion
destination port and preferred Incoterm
What happens next
datasheet and price within 24 hours
drawings for your approval
production after drawing approval and advance payment, on the date confirmed in the quotation
routine tests and test report; witness test on request
Jiangsu Tianhua Transformer Co., Ltd. designs, builds and tests this transformer in its own 107,000 m² plant in Xuzhou, Jiangsu, China. Founded in 2013, Tianhua is a manufacturer, not a trading company: you deal directly with our engineers, and inspectors are welcome to witness the factory acceptance test.
500+ employees, including 7 senior engineers
ISO 9001 quality system; IEC, IEEE / ANSI and GB designs
Why use split winding instead of two transformers?
One unit costs less, needs less space and still isolates faults between the two LV buses.
How long does the split-winding transformer take to make?
Production starts after drawing approval and advance payment. The delivery date depends on rating and quantity and is confirmed in the quotation.
Can the split-winding transformer be built to my specification?
Yes. Rating, voltage ratio, vector group, impedance, losses, accessories and dimensions can be designed to your specification and standard.
How is the split-winding transformer shipped?
Smaller units can ship oil-filled. Large power transformers are usually shipped without oil and filled with dry gas, with radiators, bushings and conservator packed separately, by break-bulk sea freight.
What warranty does Tianhua give?
The warranty is 1 to 2 years depending on the product and size, confirmed in the quotation and sales contract.