Factory-direct transformer manufacturer · Xuzhou, China

IEC 60076 · IEEE C57.12 · 50 Hz and 60 Hz designs

SC(B)12 Cast Resin Dry-Type Transformer, 10kV, 30–2,500 kVA

SC(B)12 Cast Resin Dry-Type Transformer, 10kV, 30–2,500 kVA

Specifications

Quick answer

The SC(B)12 is an epoxy cast resin dry-type transformer for 6–10 kV networks, rated 30–2,500 kVA. Its no-load loss is over 20% lower than SC(B)11 and noise 10–15 dB below JB/T 10088-2004, with partial discharge controlled to 5 pC. Made by Jiangsu Tianhua Transformer Co., Ltd. in Xuzhou, China.

SeriesSC(B)12, three-phase epoxy cast resin
Rating30–2,500 kVA
HV / LV6 / 6.3 / 10 kV to 0.4 kV
Vector groupYyn0 or Dyn11
Partial discharge≤5 pC
CertificationNational PCCC energy-saving certified product
ManufacturerJiangsu Tianhua Transformer Co., Ltd., Xuzhou, China

Get a quote in 24 hoursEmail our engineers

Key advantages · Type designation · SC(B)12 10kV rating table · How to order · FAQ

Key advantages

  • No-load loss over 20% below SC(B)11
  • Noise 10–15 dB below JB/T 10088-2004
  • Vacuum resin mixing and casting for partial discharge ≤5 pC
  • Flame-retardant, explosion-proof, self-extinguishing coils
  • High mechanical strength for sudden short circuits
  • Maintenance-free and economical to run

Type designation: SC(B)12-□/□

  • S: three-phase
  • C: epoxy resin cast
  • B: low-voltage foil winding
  • 12: performance level code
  • □: rated capacity (kVA) / voltage class (kV)

SC(B)12 10kV rating table

ModelkVANo-load loss (W)Load loss 120°C (W)Load loss 145°C (W)No-load current (%)Impedance (%)
SC12-30301507107601.74.0
SC12-50502151,0001,0701.74.0
SC12-80802951,3801,4801.284.0
SC12-1001003201,5701,6901.284.0
SC12-1251253751,8501,9801.114.0
SC(B)12-1601604302,1302,2801.114.0
SC(B)12-2002004952,5302,7100.944.0
SC(B)12-2502505752,7602,9600.944.0
SC(B)12-3153157053,4703,7300.854.0
SC(B)12-4004007853,9904,2800.854.0
SC(B)12-5005009304,8805,2300.854.0
SC(B)12-6306301,0705,8806,2900.724.0
SC(B)12-6306301,0405,9606,4000.726.0
SC(B)12-8008001,2106,9607,4600.726.0
SC(B)12-10001,0001,4108,1308,7600.726.0
SC(B)12-12501,2501,6709,69010,3700.726.0
SC(B)12-16001,6001,96011,73012,5800.726.0
SC(B)12-20002,0002,44014,45015,5600.66.0
SC(B)12-25002,5002,88017,17018,4500.66.0

630 kVA is listed with 4% and 6% impedance.

Data from the Tianhua product catalogue. Capacity, voltage ratio, vector group, impedance, losses and dimensions can be designed to your specification.

Applications

  • Power stations and plants
  • Hospitals, airports and tunnels
  • Chemical plants and nuclear power plants

Standards and testing

Designed and tested to GB 1094.11 and IEC 60076-11. Routine tests on every unit before shipment, including partial discharge measurement, with the test report supplied. Type tests and witness testing on request.

How to order

Send us

  • rated power and quantity
  • primary and secondary voltage, vector group and tapping range
  • standard (IEC, IEEE / ANSI, GB or your utility specification) and frequency
  • any loss limits or efficiency rule
  • site conditions: altitude, ambient temperature, indoor or outdoor, corrosion
  • destination port and preferred Incoterm

What happens next

  • datasheet and price within 24 hours
  • drawings for your approval
  • production after drawing approval and advance payment, on the date confirmed in the quotation
  • routine tests and test report; witness test on request
  • export packing and shipping

Shipping policy · Terms and conditions

Who makes this transformer

Transformer workshop at the Tianhua factory in Xuzhou, China

Jiangsu Tianhua Transformer Co., Ltd. designs, builds and tests this transformer in its own 107,000 m² plant in Xuzhou, Jiangsu, China. Founded in 2013, Tianhua is a manufacturer, not a trading company: you deal directly with our engineers, and inspectors are welcome to witness the factory acceptance test.

  • 500+ employees, including 7 senior engineers
  • ISO 9001 quality system; IEC, IEEE / ANSI and GB designs
  • Exported to more than 30 countries and regions

About Tianhua · Factory and testing · Certificates · Projects

Frequently asked questions

What is the no-load loss of an SCB12-800?

1,210 W, with load loss 6,960 W at 120°C and 6% impedance.

How quiet is the SC(B)12?

10–15 dB below the JB/T 10088-2004 limits for 6–220 kV transformers.

SCB12 or SCB13?

SCB13 lowers losses again (for example 1,095 W against 1,210 W no-load at 800 kVA). Choose SCB13 or SCB14/18 where losses are evaluated.

How long does the SC(B)12 dry-type transformer take to make?

Production starts after drawing approval and advance payment. The delivery date depends on rating and quantity and is confirmed in the quotation.

Can the SC(B)12 dry-type transformer be built to my specification?

Yes. Rating, voltage ratio, vector group, impedance, losses, accessories and dimensions can be designed to your specification and standard.

How is the SC(B)12 dry-type transformer shipped?

In a container, in a closed wooden case that protects it from moisture and dust. The enclosure is fitted or packed separately.

What warranty does Tianhua give?

The warranty is 1 to 2 years depending on the product and size, confirmed in the quotation and sales contract.

Get a quotation for the SC(B)12 dry-type transformer

Send capacity, voltage ratio, standard, quantity and destination. Our engineers reply with a datasheet and price within 24 hours.

Email sale@thatransformer.comWhatsAppCall Ivy Xiao

Data from the Tianhua product catalogue. Written by the Tianhua Transformer engineering team, Xuzhou, China. Last updated November 2026.

Routine test report

Every unit tested before shipment

Factory-direct

Built in our Xuzhou plant

Built to your spec

IEC, IEEE/ANSI or GB

Quote in 24 hours

Datasheet and price from our engineers

More from our factory

Power, distribution, dry-type and substation equipment, all designed, built and tested in our Xuzhou plant.

View all products
Need several units or a full project?

Send your single-line diagram or bill of quantities. Our engineers reply with a datasheet and price within 24 hours.